Load time: 8/28/2006 12:17 Read time: 8/28/2006 12:17 Kinetic read cycle: 1 of 1 Read start delay time: 0 s Time delay between kinetic reads: Barcode: Method ID: DNA-Tech Plate ID: #664 Comment: standard Microplate format: Packard 384 Shake time: 0 s Temperature: 31.4 C Instrument tag: Serial number: AD2123 Read sequence: column Mode sequence: plate Detection mode: f4 Light sensor: HC-120 Excitation side: Top Emission side: Top Lamp: Continuous Readings per well: 1 Time between readings: Integration time: 100000 us Attenuator mode: m Motion settling time: 25 ms Z Height: 0 mm Bottom Excitation filter: 1 Fluorescein 485 nm Emission filter: 1 Fluorescein 530 nm Beamsplitter: Top Fluorescein 505 Excitation polarizer filter: o Emission polarizer filter: o Detector counting: SmartRead Flash lamp voltage: Delay after flash: Sensitivity setting: 2 A/D converter gain: x1 Integrating gain: x1 Max cps: 16557055 cps Min counts: 4854 counts Well list: r0(a1:f1) = (f4(a1:f1)) Data: RAW DATA Units: rfu Display format: %.9e 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 A 1.66E+09 B 1.64E+08 C 2.26E+07 D 6.66E+06 E 4.85E+06 F 1.30E+07 G H I J K L M N O P Load time: 8/28/2006 12:24 Read time: 8/28/2006 12:24 Kinetic read cycle: 1 of 1 Read start delay time: 0 s Time delay between kinetic reads: Barcode: Method ID: DNA-Tech Plate ID: #665 Comment: standard Microplate format: Packard 384 Shake time: 0 s Temperature: 31.5 C Instrument tag: Serial number: AD2123 Read sequence: column Mode sequence: plate Detection mode: f4 Light sensor: HC-120 Excitation side: Top Emission side: Top Lamp: Continuous Readings per well: 1 Time between readings: Integration time: 100000 us Attenuator mode: m Motion settling time: 25 ms Z Height: 0 mm Bottom Excitation filter: 1 Fluorescein 485 nm Emission filter: 1 Fluorescein 530 nm Beamsplitter: Top Fluorescein 505 Excitation polarizer filter: o Emission polarizer filter: o Detector counting: SmartRead Flash lamp voltage: Delay after flash: Sensitivity setting: 2 A/D converter gain: x1 Integrating gain: x1 Max cps: 16747466 cps Min counts: 580 counts Well list: r0(a1:g1) = counts(f4(a1:g1)) Data: RAW DATA Units: counts Display format: %.9e 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 A 1.56E+05 B 1.56E+05 C 2.52E+04 D 6.65E+03 E 4.88E+03 F 1.42E+04 G 5.80E+02 H I J K L M N O P Load time: 8/28/2006 12:27 Read time: 8/28/2006 12:27 Kinetic read cycle: 1 of 1 Read start delay time: 0 s Time delay between kinetic reads: Barcode: Method ID: DNA-Tech Plate ID: #666 Comment: standard Microplate format: Packard 384 Shake time: 0 s Temperature: 31.5 C Instrument tag: Serial number: AD2123 Read sequence: column Mode sequence: plate Detection mode: f4 Light sensor: HC-120 Excitation side: Top Emission side: Top Lamp: Continuous Readings per well: 1 Time between readings: Integration time: 100000 us Attenuator mode: m Motion settling time: 25 ms Z Height: 0 mm Bottom Excitation filter: 1 Fluorescein 485 nm Emission filter: 1 Fluorescein 530 nm Beamsplitter: Top Fluorescein 505 Excitation polarizer filter: o Emission polarizer filter: o Detector counting: SmartRead Flash lamp voltage: Delay after flash: Sensitivity setting: 2 A/D converter gain: x1 Integrating gain: x1 Max cps: 16405881 cps Min counts: 590 counts Well list: r0(a1:g1) = (f4(a1:g1)) Data: RAW DATA Units: rfu Display format: %.9e 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 A 1.64E+09 B 1.62E+08 C 2.57E+07 D 6.65E+06 E 4.72E+06 F 1.34E+07 G 5.90E+05 H I J K L M N O P