Load time:	07/06/2007 01:31:13 PM
Read time:	07/06/2007 01:31:21 PM
Kinetic read cycle:	1  of  1
Read start delay time:	0	s
Time delay between kinetic reads:	<n/a>
Barcode:	ERROR
Method ID:	Jeremy
Plate ID:	#1272
Comment:	new comment
Microplate format:	Nunc-Immuno Flat Bottom
Shake time:	0	s
Temperature:	31.9	C
Instrument tag:	
Serial number:	AD2123
Read sequence:	row
Mode sequence:	plate
Detection mode:	a2
Light sensor:	PhotoDiode
Excitation side:	Top
Emission side:	Top
Lamp:	Continuous
Flash lamp voltage:	<n/a>
Readings per well:	1
Time between readings:	<n/a>
Integration time:	18540	us
Delay after flash:	<n/a>
Motion settling time:	0	ms
Z Height:	5	mm	Numeric
Excitation filter:	2	Europium 360 nm
Beamsplitter:	Top	Fluorescein 505
Excitation polarizer filter:	o
Photodiode capacitor:	1
Photodiode resistor:	7
Photodiode gain:	x2
Photodiode remote gain:	x100
Max cps:	14271	cps
Min counts:	11879	counts
Dark Count reading:	801	counts
Well list:	r0(a1:h12) = cps(a2(a1:h12))
Data:	RAW DATA
Units:	Counts
Display format:	%.0f
	1	2	3	4	5	6	7	8	9	10	11	12
A	13571	13410	13168	13450	13355	13028	13020	13622	12913	13351	13454	13259
B	13621	13348	13328	13634	13811	12976	13061	13499	13322	13519	13388	13181
C	13872	13653	13281	13250	13266	11879	13848	13419	13473	12968	13187	12906
D	14024	13184	13154	12949	14164	13097	13395	13096	13388	13512	12855	13306
E	14171	13408	13053	13686	13943	13867	13546	12965	13584	13064	13306	13167
F	13463	11929	12802	14060	13577	13039	13009	12207	13834	13372	12150	12988
G	13885	13029	13238	14145	13599	14271	13434	13634	13252	12918	13584	13461
H	13564	13528	13577	13631	13929	13661	13782	13809	13382	13376	13824	13773
Well list:	r2(a1:h12) = 0 - log10((a2(a1:h12)-803)/(14289 - 803))
Data:	0 (Abs factor) - Log10( (Sample 1 - Dark counts) / (Bright counts - Dark counts))
Units:	O.D.
Display format:	%.9e
	1	2	3	4	5	6	7	8	9	10	11	12
A	2.376028133e-002	2.927140251e-002	3.768903464e-002	2.789563678e-002	3.117022476e-002	4.263428754e-002	4.291858146e-002	2.202900780e-002	4.673901220e-002	3.130864531e-002	2.775829961e-002	3.450455578e-002
B	2.206288809e-002	3.141248969e-002	3.210542080e-002	2.162265036e-002	1.567262709e-002	4.448553332e-002	4.146353832e-002	2.621624159e-002	3.231351591e-002	2.553263610e-002	3.002993546e-002	3.723267698e-002
C	1.364079738e-002	2.098002767e-002	3.373817405e-002	3.481846579e-002	3.426056032e-002	8.550020827e-002	1.443907190e-002	2.896147502e-002	2.710654046e-002	4.477104207e-002	3.702221200e-002	4.699012205e-002
D	8.618850111e-003	3.712743174e-002	3.818103362e-002	4.544987855e-002	4.044191346e-003	4.018994656e-002	2.978844033e-002	4.022527372e-002	3.002993546e-002	2.577177564e-002	4.882403234e-002	3.286892416e-002
E	3.816718455e-003	2.934030533e-002	4.174706664e-002	1.986614855e-002	1.128779012e-002	1.380698361e-002	2.461147223e-002	4.487815626e-002	2.331832049e-002	4.135726291e-002	3.286892416e-002	3.772415895e-002
F	2.744944966e-002	8.354409974e-002	5.073810201e-002	7.437899059e-003	2.355624352e-002	4.224368703e-002	4.330978972e-002	7.282594670e-002	1.490541056e-002	3.058242911e-002	7.500210048e-002	4.405762182e-002
G	1.320901054e-002	4.259876389e-002	3.523736573e-002	4.662219024e-003	2.280892393e-002	5.800476246e-004	2.844542020e-002	2.162265036e-002	3.474868840e-002	4.655973687e-002	2.331832049e-002	2.751806400e-002
H	2.399844667e-002	2.522536433e-002	2.355624352e-002	2.172420408e-002	1.175075542e-002	2.070973392e-002	1.664192291e-002	1.573940567e-002	3.023703822e-002	3.044423979e-002	1.523881644e-002	1.694317926e-002
Load time:	07/06/2007 01:34:14 PM
Read time:	07/06/2007 01:34:23 PM
Kinetic read cycle:	1  of  1
Read start delay time:	0	s
Time delay between kinetic reads:	<n/a>
Barcode:	ERROR
Method ID:	Jeremy
Plate ID:	#1273
Comment:	new comment
Microplate format:	Nunc-Immuno Flat Bottom
Shake time:	0	s
Temperature:	31.9	C
Instrument tag:	
Serial number:	AD2123
Read sequence:	row
Mode sequence:	plate
Detection mode:	a2
Light sensor:	PhotoDiode
Excitation side:	Top
Emission side:	Top
Lamp:	Continuous
Flash lamp voltage:	<n/a>
Readings per well:	1
Time between readings:	<n/a>
Integration time:	18540	us
Delay after flash:	<n/a>
Motion settling time:	0	ms
Z Height:	5	mm	Numeric
Excitation filter:	2	Europium 360 nm
Beamsplitter:	Top	Fluorescein 505
Excitation polarizer filter:	o
Photodiode capacitor:	1
Photodiode resistor:	7
Photodiode gain:	x2
Photodiode remote gain:	x100
Max cps:	14372	cps
Min counts:	11830	counts
Dark Count reading:	803	counts
Well list:	r0(a1:h12) = cps(a2(a1:h12))
Data:	RAW DATA
Units:	Counts
Display format:	%.0f
	1	2	3	4	5	6	7	8	9	10	11	12
A	13439	13470	13191	13405	13426	12947	12882	13479	13189	13411	13669	13639
B	13556	13075	13195	13657	14114	13259	13204	13275	13456	13186	13147	13206
C	13934	13785	13238	13185	13252	11830	13660	13520	13469	13114	13117	13195
D	13786	13220	13162	12977	14159	13144	13365	13209	13249	13410	13156	13559
E	13851	13404	13179	13648	13947	14162	13465	13071	13546	13012	13537	13259
F	13542	11840	12732	13986	13393	13027	12931	12220	13587	13303	12351	13068
G	13705	13215	13209	14198	13682	14372	13579	13920	13408	12986	13458	13384
H	13622	13229	13645	13838	14062	13512	13738	13653	13720	13602	13761	13742
Well list:	r2(a1:h12) = 0 - log10((a2(a1:h12)-802)/(14332 - 802))
Data:	0 (Abs factor) - Log10( (Sample 1 - Dark counts) / (Bright counts - Dark counts))
Units:	O.D.
Display format:	%.9e
	1	2	3	4	5	6	7	8	9	10	11	12
A	2.965381111e-002	2.858974190e-002	3.826154365e-002	3.082386034e-002	3.010081073e-002	4.690027746e-002	4.923086231e-002	2.828130627e-002	3.833165900e-002	3.061715187e-002	2.182049564e-002	2.283425539e-002
B	2.565138395e-002	4.234706238e-002	3.812134690e-002	2.222571562e-002	7.054487651e-003	3.588433215e-002	3.780606959e-002	3.532687425e-002	2.906996647e-002	3.843685326e-002	3.980670233e-002	3.773603903e-002
C	1.296692254e-002	1.792273950e-002	3.661708323e-002	3.847192367e-002	3.612844517e-002	8.880103916e-002	2.212437517e-002	2.687897595e-002	2.862402605e-002	4.096918977e-002	4.086338042e-002	3.812134690e-002
D	1.788928978e-002	3.724614109e-002	3.927932584e-002	4.582882671e-002	5.588870625e-003	3.991225452e-002	3.220443682e-002	3.763101437e-002	3.623310705e-002	3.065159645e-002	3.949019960e-002	2.554924107e-002
E	1.572056547e-002	3.085832132e-002	3.868240566e-002	2.252987892e-002	1.253720616e-002	5.491338458e-003	2.876118972e-002	4.248863014e-002	2.599203380e-002	4.458213265e-002	2.629884730e-002	3.588433215e-002
F	2.612836860e-002	8.840740687e-002	5.465735293e-002	1.125060224e-002	3.123757267e-002	4.404892880e-002	4.747280054e-002	7.370775793e-002	2.459706424e-002	3.435304142e-002	6.875341525e-002	4.259483625e-002
G	2.060709932e-002	3.742104121e-002	3.763101437e-002	4.322657730e-003	2.138193357e-002	-1.282051062e-003	2.486890180e-002	1.343017003e-002	3.072049381e-002	4.550790627e-002	2.900133044e-002	3.154811575e-002
H	2.340977141e-002	3.693149826e-002	2.263131404e-002	1.615344480e-002	8.754272529e-003	2.715224604e-002	1.949778970e-002	2.236087301e-002	2.010251639e-002	2.408782695e-002	1.872630673e-002	1.936352026e-002