Load time: 04/13/2009 10:22:11 AM Read time: 04/13/2009 10:22:11 AM Kinetic read cycle: 1 of 1 Read start delay time: 0 s Time delay between kinetic reads: Barcode: ERROR Method ID: Daves Method Plate ID: #75 Comment: Microplate format: Packard-Optiplate 96 Flat White PS Shake time: 0 s Temperature: 30.7 C Instrument tag: Serial number: AD2123 Read sequence: row Mode sequence: plate Detection mode: l2 Light sensor: HC-124 Excitation side: Top Emission side: Top Lamp: None Readings per well: 1 Time between readings: Integration time: 1000000 us Attenuator mode: o Motion settling time: 0 ms Luminescence height: 2 mm Numeric Luminescence aperture: 96 Max cps: 3379 cps Min counts: 136 counts Dark Count reading: 19 counts Well list: r0(a1:h12) = (l2(a1:h12)) Data: RAW DATA Units: rlu Display format: %.2f 1 2 3 4 5 6 7 8 9 10 11 12 A 332.00 261.00 533.00 1985.00 1453.00 743.00 744.00 235.00 346.00 934.00 556.00 564.00 B 214.00 258.00 388.00 611.00 727.00 920.00 264.00 545.00 216.00 874.00 624.00 648.00 C 136.00 539.00 290.00 880.00 1108.00 805.00 359.00 483.00 281.00 947.00 440.00 614.00 D 160.00 2022.00 224.00 982.00 451.00 3379.00 387.00 423.00 184.00 603.00 424.00 434.00 E 288.00 169.00 329.00 1161.00 705.00 900.00 456.00 327.00 352.00 1163.00 619.00 455.00 F 274.00 868.00 358.00 1184.00 802.00 579.00 873.00 427.00 525.00 1799.00 935.00 268.00 G 160.00 341.00 1696.00 1442.00 555.00 955.00 640.00 288.00 557.00 467.00 368.00 852.00 H 389.00 426.00 320.00 1025.00 1104.00 523.00 499.00 213.00 388.00 722.00 987.00 2721.00 Load time: 04/13/2009 10:25:56 AM Read time: 04/13/2009 10:25:56 AM Kinetic read cycle: 1 of 1 Read start delay time: 0 s Time delay between kinetic reads: Barcode: ERROR Method ID: Daves Method Plate ID: #76 Comment: Microplate format: Packard-Optiplate 96 Flat White PS Shake time: 0 s Temperature: 30.8 C Instrument tag: Serial number: AD2123 Read sequence: row Mode sequence: plate Detection mode: l2 Light sensor: HC-124 Excitation side: Top Emission side: Top Lamp: None Readings per well: 1 Time between readings: Integration time: 1000000 us Attenuator mode: o Motion settling time: 0 ms Luminescence height: 2 mm Numeric Luminescence aperture: 96 Max cps: 85937 cps Min counts: 92 counts Dark Count reading: 35 counts Well list: r0(a1:h12) = (l2(a1:h12)) Data: RAW DATA Units: rlu Display format: %.2f 1 2 3 4 5 6 7 8 9 10 11 12 A 5399.00 2545.00 3552.00 4106.00 2725.00 2240.00 6042.00 4902.00 4869.00 816.00 198.00 1114.00 B 498.00 339.00 209.00 210.00 645.00 377.00 429.00 262.00 269.00 1456.00 208.00 544.00 C 966.00 180.00 219.00 356.00 242.00 92.00 228.00 725.00 809.00 1210.00 1204.00 2032.00 D 160.00 128.00 327.00 225.00 309.00 320.00 371.00 500.00 802.00 738.00 1072.00 424.00 E 5117.00 6549.00 7029.00 10151.00 5472.00 8637.00 9824.00 11965.00 85937.00 1136.00 2017.00 856.00 F 715.00 808.00 679.00 640.00 651.00 331.00 1744.00 576.00 3879.00 451.00 874.00 976.00 G 164.00 468.00 244.00 100.00 192.00 197.00 342.00 336.00 2544.00 1244.00 288.00 1008.00 H 141.00 435.00 221.00 153.00 118.00 220.00 274.00 275.00 361.00 448.00 304.00 923.00 Load time: 04/13/2009 10:30:33 AM Read time: 04/13/2009 10:30:33 AM Kinetic read cycle: 1 of 1 Read start delay time: 0 s Time delay between kinetic reads: Barcode: ERROR Method ID: Daves Method Plate ID: #77 Comment: Microplate format: Packard-Optiplate 96 Flat White PS Shake time: 0 s Temperature: 30.9 C Instrument tag: Serial number: AD2123 Read sequence: row Mode sequence: plate Detection mode: l2 Light sensor: HC-124 Excitation side: Top Emission side: Top Lamp: None Readings per well: 1 Time between readings: Integration time: 1000000 us Attenuator mode: o Motion settling time: 0 ms Luminescence height: 2 mm Numeric Luminescence aperture: 96 Max cps: 9075 cps Min counts: 69 counts Dark Count reading: 24 counts Well list: r0(a3:h8) = (l2(a3:h8)) Data: RAW DATA Units: rlu Display format: %.2f 1 2 3 4 5 6 7 8 9 10 11 12 A 585.00 245.00 4471.00 107.00 134.00 112.00 B 196.00 539.00 273.00 112.00 113.00 116.00 C 395.00 310.00 297.00 96.00 87.00 108.00 D 604.00 325.00 9075.00 101.00 96.00 96.00 E 240.00 569.00 957.00 72.00 74.00 76.00 F 492.00 346.00 451.00 72.00 69.00 72.00 G 5349.00 534.00 503.00 477.00 721.00 1009.00 H 2774.00 283.00 200.00 450.00 421.00 915.00 Load time: 04/13/2009 10:38:17 AM Read time: 04/13/2009 10:38:17 AM Kinetic read cycle: 1 of 1 Read start delay time: 0 s Time delay between kinetic reads: Barcode: ERROR Method ID: Daves Method Plate ID: #78 Comment: Microplate format: Packard-Optiplate 96 Flat White PS Shake time: 0 s Temperature: 31.1 C Instrument tag: Serial number: AD2123 Read sequence: row Mode sequence: plate Detection mode: l2 Light sensor: HC-124 Excitation side: Top Emission side: Top Lamp: None Readings per well: 1 Time between readings: Integration time: 1000000 us Attenuator mode: o Motion settling time: 0 ms Luminescence height: 2 mm Numeric Luminescence aperture: 96 Max cps: 10736 cps Min counts: 156 counts Dark Count reading: 26 counts Well list: r0(a3:h8) = (l2(a3:h8)) Data: RAW DATA Units: rlu Display format: %.2f 1 2 3 4 5 6 7 8 9 10 11 12 A 460.00 200.00 3056.00 666.00 4182.00 5645.00 B 194.00 331.00 245.00 273.00 316.00 242.00 C 288.00 215.00 227.00 242.00 371.00 156.00 D 406.00 266.00 5232.00 6948.00 10736.00 3132.00 E 208.00 391.00 618.00 981.00 480.00 1035.00 F 361.00 246.00 294.00 224.00 250.00 198.00 G 3584.00 436.00 403.00 381.00 585.00 762.00 H 1792.00 197.00 173.00 357.00 397.00 683.00